Skip to main content

Table 1 Compare the three segmentation models’ performance in four measurements: precision, recall, DSC and Jaccard index

From: Hierarchical combinatorial deep learning architecture for pancreas segmentation of medical computed tomography cancer images

  PRECISION RECALL DSC JACCARD
  mean Std mean Std mean Std mean Std
rcf 74.35 18.97 79.83 16.70 74.91 15.25 61.98 17.44
ours 76.83 18.53 78.74 17.19 75.92 15.17 63.29 17.45
ours-ms 77.36 17.96 79.12 16.27 76.36 14.34 63.72 17.05