Table 4 Values of the kinetic parameters, obtained from [24]

From: Modeling biological systems with uncertain kinetic data using fuzzy continuous Petri nets

Parameter Value Unit
k 1p 3.49 ml/#s
k 1m 0.19 s −1
k 2p 1.07 ml/#s
k 2m 10−9 s −1
k 3p 0.17 ml/#s
k 3m 1.21×10−6 s −1
k 4 8.3×10−3 s −1
k 5p 9.74 ml/#s
k 5m 3.56 s −1
k 6 2.33 ml/#s
k 7 4.31×10−5 ml/#s
k 8 2.73×10−7 ml/#s
k 9 3.2×10−5 s −1
k 10 \( \left (1-\frac {0.4}{{{e}^{T-37}}} \right)\times {{1.4}^{T-37}}\times 1.45\times {{10}^{-5}}\) s −1
k 11p 3.32×10−3 ml/#s
k 11m 4.44 s −1
k 12 13.94 s −1